MV1455 Differential Relay Trainer

Beskrivning

MV1455 Differential Relay Trainer unit is intended for advanced training in modern differential protection technology. The differential relay trainer is equipped with the fully IEC61850 compliant ABB RET615 protective relay which is one of the most sophisticated protection unit in the product family of intelligent electronic devices (IEDs). RET615 is designed for differential protection of transformers, generators, line sections and their combinations.

The use of a highly advanced IED enables great possibilities to perform a wide range of laboratory experiments.

The unit is encased in a robust chassis of sheet metal and is equipped with a large graphical Human Monitoring Interface (HMI) with a single line diagram. Control, monitoring and parameter setting can be configured either from the HMI or from a PC by means of the standardized Ethernet interface.

The protective relay RET615 used in MV1455 enables the student to learn and explore how to protect a variety of different power transformer connections with a differential protection scheme.

General Features

  • Colour coded power inlet- and outlets for easy recognition of each phase.
  • Three power lines; 1 incoming power line and 2 outgoing. Each line contain three phases L1, L2, L3 and Neutral wire.
  • Accessible protective ground outlets on the front as well at the back of the unit.
  • 12 current transformers which enables the student to study various CT-connections.
  • Protection and Control IED Manager PCM600: Advanced software for configuration and parameter setting.
  • Mimic diagrams of the circuit along with large clear symbols printed on the front panel
  • Front panel switches that enables the student to test differential protection on a dual-busbar.
Technical Specification
Power Supply:230V/50Hz. Possibilty to power compatible device. (see appendix A)
Power bus:(3-ph) 400V AC/ 2A with 4 mm banana plugs.
Size :357 x 483 x 420 mm
Weight:37 kg

 

MV1455-COMP PC with installed and pre-programmed software for MV1455

Appendix A  Power supply

If a compatible device is used in conjunction with the MV1455 it can be powered from the MV1455 unit instead of occupying an additional wall outlet.

Recommended equipment for MV1455

Cat. CodeDescriptionpcpage
MV1455Line Multi Protection Trainer116
MV1455-COMPPC with installed & pre-programmed software for MV1450116
Recommended peripheral equipment for MV1450
MV1103Variable Transformer, 3-phase119
MV1429Terminal Board130
MV1100-235Load Resistor 3-ph, 3.3kW121
MV1101Load Reactor, 3-phase 2.5kVAr121
MV1102Load Capacitor, 3-phase, 2.8 kVAr122
MV1500Load Switch, 3-pole 16A130
MV1957Rhestat 200W, 5 ohm, 6.3A323
MV1959Rheostat 200W, 50 ohm,, 2A123
MV1400Push Button Panel128
MV1911Transformer 1-phase, 1kVA, 50-60 Hz129
MV1915Transformer 3-phase, 2kVA, 50-60 Hz129
MV1922/23Ammeter 0-10A, AC/DC530
MV1926Voltmeter 0-50-250-500V AC/DC230
MAT220349Digital Clamp Meter AC / DC current130
DMC9Digital Multimeter131
MV1830-HFFlex Set, 100 Safety Leads, Safety Plugs133
MV1904Flex Stand133

?